Data · dataset · 2019
The training set and test set data of PSO-LM-Elman neural network
Listed in Teesside University Research Data Repository
The regulating valve training set and test set data were gained from the results of H. Zhu regulating valve dynamic performance test.
Description
The regulating valve opening range is 10%-100%, and the step length is 10%. The pressure drop control range is 20-260 kPa, and the pressure drop step is 20 kPa.
The flow rate range is 0.3-2.9 m^3⁄h.
Links
Where it is published
- DOI doi.org/10.17632/jms3zkrx4w.1 ↗
DOI / persistent id · from researchdata tees ac uk
Catalogue records · 1
- OAI-PMH record data.mendeley.com/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Adata… ↗
metadata API · from researchdata tees ac uk
Topics
- From keywords
- Earth & Environmental Science
Provenance · 1 source records, 6 field assertions
| Source | Key | Last seen | Raw |
|---|---|---|---|
| Teesside University Research Data Repository | oai:data.mendeley.com/jms3zkrx4w.1 | 20 h ago | JSON v1 |
| Field | Assertion | Extractor | Evidence |
|---|---|---|---|
| access_level | source · researchdata tees ac uk | connector:researchdata_tees_ac_uk@1.0.0 | |
| concepts[field].local:field:earth-environmental | mapping · researchdata tees ac uk | connector:researchdata_tees_ac_uk@1.0.0 | |
| description | source · researchdata tees ac uk | connector:researchdata_tees_ac_uk@1.0.0 | /metadata/dc/description |
| license | source · researchdata tees ac uk | connector:researchdata_tees_ac_uk@1.0.0 | /metadata/dc/rights |
| publication_date | source · researchdata tees ac uk | connector:researchdata_tees_ac_uk@1.0.0 | |
| title | source · researchdata tees ac uk | connector:researchdata_tees_ac_uk@1.0.0 | /metadata/dc/title |