Optimization of an enclosed gas analyzer sampling system for measuring eddy covariance fluxes of H₂O and CO₂

Listed in National Center for Atmospheric Research

Several initiatives are currently emerging to observe the exchange of energy and matter between the earth's surface and atmosphere standardized over larger space and time domains.

Description

For example, the National Ecological Observatory Network (NEON) and the Integrated Carbon Observing System (ICOS) are set to provide the ability of unbiased ecological inference across ecoclimatic zones and decades by deploying highly scalable and robust instruments and data processing.

In the construction of these observatories, enclosed infrared gas analyzers are widely employed for eddy covariance applications. While these sensors represent a substantial improvement compared to their open- and closed-path predecessors, remaining high-frequency attenuation varies with site properties and gas sampling systems, and requires correction. Here, we show that components of the gas sampling system can substantially contribute to such high-frequency attenuation, but their effects can be significantly reduced by careful system design.

Read the rest (4 more)

From laboratory tests we determine the frequency at which signal attenuation reaches 50 % for individual parts of the gas sampling system. For different models of rain caps and particulate filters, this frequency falls into ranges of 2.5-16.5 Hz for CO₂, 2.4-14.3 Hz for H₂O, and 8.3-21.8 Hz for CO₂, 1.4-19.9 Hz for H2O, respectively. A short and thin stainless steel intake tube was found to not limit frequency response, with 50 % attenuation occurring at frequencies well above 10 Hz for both H₂O and CO₂.

From field tests we found that heating the intake tube and particulate filter continuously with 4 W was effective, and reduced the occurrence of problematic relative humidity levels (RH  > 60 %) by 50 % in the infrared gas analyzer cell. No further improvement of H₂O frequency response was found for heating in excess of 4 W. These laboratory and field tests were reconciled using resistor-capacitor theory, and NEON's final gas sampling system was developed on this basis.

The design consists of the stainless steel intake tube, a pleated mesh particulate filter and a low-volume rain cap in combination with 4 W of heating and insulation. In comparison to the original design, this reduced the high-frequency attenuation for H₂O by  ≈ 3∕4, and the remaining cospectral correction did not exceed 3 %, even at high relative humidity (95 %). The standardized design can be used across a wide range of ecoclimates and site layouts, and maximizes practicability due to minimal flow resistance and maintenance needs.

Furthermore, due to minimal high-frequency spectral loss, it supports the routine application of adaptive correction procedures, and enables largely automated data processing across sites.

Links

Get the data

Where it is published

Catalogue records · 1

Topics

Inferred from text
Climate change science 73%
Provenance · 1 source records, 8 field assertions
SourceKeyLast seenRaw
National Center for Atmospheric Researchd342e894-7ea1-45cd-93bd-7278d84ed85c10 d agoJSON v1
FieldAssertionExtractorEvidence
concepts[field].anzsrc:group:3702enrichment · data ucar edutaxonomy-embedding@1.1.0title+keywords+description (73%)
concepts[field].local:field:earth-environmentalmapping · data ucar educonnector:data_ucar_edu@1.0.0
concepts[field].local:field:ocean-atmosphericmapping · data ucar educonnector:data_ucar_edu@1.0.0
created_datesource · data ucar educonnector:data_ucar_edu@1.0.0
descriptionsource · data ucar educonnector:data_ucar_edu@1.0.0/notes
publication_datesource · data ucar educonnector:data_ucar_edu@1.0.0
titlesource · data ucar educonnector:data_ucar_edu@1.0.0/title
updated_datesource · data ucar educonnector:data_ucar_edu@1.0.0