Data · dataset · 2025
Comparative Study between Self-Developed Plastic Scintillators and EJ-276D
Listed in ScienceDB
[Background] As one of important neutron-sensitive scintillators, plastic scintillator has been widely used in applications such as non-destructive testing, reactor monitoring, and nuclear physics.
Description
[Purpose] This study aims to conduct comparative performance tests between the Ø2.54 cm×2.54 cm and Ø5.08 cm×5.08 cm self-developed plastic scintillators (SD-PS) and EJ-276D. [Methods] A testing platform was established using photomultiplier tube (PMT) and a high-speed digitizer to comparatively evaluate the radiation response performance of Ø2.54 cm×2.54 cm and Ø5.08 cm×5.08 cm self-developed right cylindrical plastic scintillators with two different formulations, alongside EJ-276D scintillators of corresponding sizes.
Energy calibration was performed for each scintillator using a 137Cs source to determine the relative light output, confirming that the reproducibility from test method was less than 5%. A 252Cf fission ionization chamber was employed to assess the neutron-gamma discrimination capability of the four plastic scintillators, and each scintillator was also utilized to measure the neutron-gamma time-of-flight spectrum of the 252Cf source, from which the Figure of Merit (FoM), relative detection efficiency, timing accuracy, and gamma misidentification were derived.
Read the rest (2 more)
[Results] The results indicate that the light yield of the Ø2.54 cm×2.54 cm self-developed plastic scintillator is comparable to that of the corresponding EJ-276D, with the Figure of Merit less by up to 10% in the 60-640 keVee energy range and detection efficiency less by 19%. The Ø5.08 cm×5.08 cm self-developed scintillator shows a 15% lower light yield compared to the corresponding EJ-276D, with the FoM less by up to 26% and detection efficiency less by 25% over the same energy range.
The timing accuracy of the Ø2.54 cm×2.54 cm and Ø5.08 cm×5.08 cm self-developed scintillators are 0.87 ns and 1.25 ns, respectively, which are superior to those of the EJ-276D (1.00 ns and 1.38 ns). For all scintillators, the gamma misidentification rate remained less than 1% at an energy threshold of 120 keVee. [Conclusions] The test results indicate that the radiation detection performance of the Ø2.54 cm×2.54 cm self-developed plastic scintillator is comparable to that of EJ-276D.
Links
Where it is published
- DOI doi.org/10.57760/sciencedb.hjs.00576 ↗
DOI / persistent id · from scidb cn
Catalogue records · 1
- OAI-PMH record scidb.cn/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=10.57760%2… ↗
metadata API · from scidb cn
Topics
- From keywords
- Earth & Environmental Science · Engineering · Humanities · Life Sciences · Social Science
Provenance · 1 source records, 10 field assertions
| Source | Key | Last seen | Raw |
|---|---|---|---|
| ScienceDB | 10.57760/sciencedb.hjs.00576 | 11 d ago | JSON v1 |
| Field | Assertion | Extractor | Evidence |
|---|---|---|---|
| access_level | source · scidb cn | connector:scidb_cn@1.0.0 | |
| concepts[field].local:field:earth-environmental | mapping · scidb cn | connector:scidb_cn@1.0.0 | |
| concepts[field].local:field:engineering | mapping · scidb cn | connector:scidb_cn@1.0.0 | |
| concepts[field].local:field:humanities | mapping · scidb cn | connector:scidb_cn@1.0.0 | |
| concepts[field].local:field:life-sciences | mapping · scidb cn | connector:scidb_cn@1.0.0 | |
| concepts[field].local:field:social-science | mapping · scidb cn | connector:scidb_cn@1.0.0 | |
| description | source · scidb cn | connector:scidb_cn@1.0.0 | /metadata/dc/description |
| license_text | source · scidb cn | connector:scidb_cn@1.0.0 | |
| publication_date | source · scidb cn | connector:scidb_cn@1.0.0 | |
| title | source · scidb cn | connector:scidb_cn@1.0.0 | /metadata/dc/title |