← Search

Data · dataset · 2026

Raw IV-curve and continuous-voltage measurements for current-ripple PEM electrolyser degradation study

Listed in Teesside University Research Data Repository

Measurement and fitted-parameter data from a 1000-hour durability campaign on four single-cell PEM water electrolysers, each supplied with a different current-ripple condition at the same 2 A mean current (PEM1 = 300 Hz, PEM2 = pure DC, PEM3 = 600 Hz, PEM4 = 1200 Hz; all at 50% ripple magnitude).

Description

Data: per-cycle IV polarisation curves (4 cells x 9 characterisations), the complete continuous ~1 Hz voltage log over the full campaign (4 cells, ~3.37 million samples each), and fitted four-parameter electrochemical model values (R_mem, alpha, i0, I_lim) with RMSE.

All files are CSV, with a README describing structure, columns, units, and the cell-to-ripple mapping.

Links

Where it is published

Catalogue records · 1

Topics

Provenance · 1 source records, 8 field assertions
SourceKeyLast seenRaw
Teesside University Research Data Repositoryoai:data.mendeley.com/93jz2rgy4d.29 h agoJSON v1
FieldAssertionExtractorEvidence
access_levelsource · researchdata tees ac ukconnector:researchdata_tees_ac_uk@1.0.0
concepts[field].anzsrc:field:340604mapping · researchdata tees ac ukvocabulary-mapper@1.0.0keywords['Electrochemistry']
concepts[field].anzsrc:field:400911mapping · researchdata tees ac ukvocabulary-mapper@1.0.0keywords['Power Electronics']
concepts[field].local:field:earth-environmentalmapping · researchdata tees ac ukconnector:researchdata_tees_ac_uk@1.0.0
descriptionsource · researchdata tees ac ukconnector:researchdata_tees_ac_uk@1.0.0/metadata/dc/description
licensesource · researchdata tees ac ukconnector:researchdata_tees_ac_uk@1.0.0/metadata/dc/rights
publication_datesource · researchdata tees ac ukconnector:researchdata_tees_ac_uk@1.0.0
titlesource · researchdata tees ac ukconnector:researchdata_tees_ac_uk@1.0.0/metadata/dc/title