Constarium
← Search

Imaging · dataset · 2016

Diagnostic Accuracy of Lateral Flow Urine LAM Assay for TB Screening of Adults with Advanced Immunosuppression Attending Routine HIV Care in South Africa

Listed in LSHTM Data Compass

Description

Background

We assessed the diagnostic accuracy of Determine TB-LAM (LF-LAM) to screen for tuberculosis among ambulatory adults established in HIV care in South Africa.

Read the rest (4 more)

Methods

A systematic sample of adults attending for HIV care, regardless of symptomatology, were enrolled in the XPHACTOR study, which tested a novel algorithm for prioritising investigation with Xpert MTB/RIF. In this substudy, restricted to participants with enrolment CD4<200x106/l, urine was stored at enrolment for later testing with LF-LAM. Sputum was sent for immediate Xpert MTB/RIF if any of: current cough, fever ≥3 weeks, body mass index (BMI)<18.5kg/m2, CD4<100x106/l (or <200x106/l if pre-ART), weight loss ≥10% or strong clinical suspicion were present; otherwise, sputum was stored for Xpert testing at study completion.

Participants were reviewed monthly, with reinvestigation if indicated, to 3 months, when sputum and blood were taken for mycobacterial culture. We defined tuberculosis as “confirmed” if Xpert, line probe assay or culture for M. tuberculosis within six months of enrolment were positive, and “clinical” if tuberculosis treatment started without microbiological confirmation. Results: Amongst 424 participants, 61% were female and 57% were taking ART (median duration 22 months); median age, CD4 and BMI were 39 years, 111x106/l, and 23 kg/m2. 56/424 (13%) participants had tuberculosis (40 confirmed, 16 clinical). 24/424 (5.7%) vs. 8/424 (1.9%) were LAM-positive using grade 1 vs. grade 2 cut-off.

Using grade 1 cut-off, sensitivity for confirmed TB (all clinical TB excluded) was 12.5% (95% CI 4.2%, 26.8%) and in CD4<100x106/l vs. CD4 ≥100x106/l was 16.7% (95% CI 4.7%, 37.4%) vs. 6.3% (95% CI 0.2%, 30.2%). Specificity was >95% irrespective of diagnostic reference standard, CD4 stratum, or whether grade 1 or grade 2 cut-off was used. Conclusion: Sensitivity of LF-LAM is too low to recommend as part of intensified case finding in ambulatory patients established in HIV care.

Links

Topics

Related

Provenance · 1 source records, 10 field assertions
SourceKeyLast seenRaw
LSHTM Data Compassoai:datacompass.lshtm.ac.uk:22210 d agoJSON v1
FieldAssertionExtractorEvidence
access_levelsource · lshtm ac ukconnector:lshtm_ac_uk@1.0.0
concepts[field].local:field:earth-environmentalmapping · lshtm ac ukconnector:lshtm_ac_uk@1.0.0
concepts[field].local:field:humanitiesmapping · lshtm ac ukconnector:lshtm_ac_uk@1.0.0
concepts[field].local:field:life-sciencesmapping · lshtm ac ukconnector:lshtm_ac_uk@1.0.0
concepts[field].local:field:medicine-healthmapping · lshtm ac ukconnector:lshtm_ac_uk@1.0.0
concepts[field].local:field:social-sciencemapping · lshtm ac ukconnector:lshtm_ac_uk@1.0.0
descriptionsource · lshtm ac ukconnector:lshtm_ac_uk@1.0.0/metadata/dc/description
licensesource · lshtm ac ukconnector:lshtm_ac_uk@1.0.0/metadata/dc/rights
publication_datesource · lshtm ac ukconnector:lshtm_ac_uk@1.0.0
titlesource · lshtm ac ukconnector:lshtm_ac_uk@1.0.0/metadata/dc/title